toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Evaporator Case|Removal and Installation|Page 6395 > < Evaporator Case|Removal and Installation|Page 6393
Page 5
background image

d. Install the suction hose piping clamp set nut.

5. INSTALL 3 CRUISE CONTROL ACTUATOR SET BOLTS

6. CONNECT CRUISE CONTROL ACTUATOR CONNECTOR

7. CHARGE REFRIGERANT TO REFRIGERATION SYSTEM

a. Evacuate air from refrigeration system.
b. Charge system with refrigerant.

Specified amount: 650 ± 50 g (22.93 ± 1.76 oz.)

8. INSPECT FOR LEAKAGE OF REFRIGERANT

Using a gas leak detector, check for leakage of refrigerant.
If there is leakage, check the tightening torque at the joints or check fitting for claw of piping clamp.

Evaporator Case|Removal and Installation|Page 6395 > < Evaporator Case|Removal and Installation|Page 6393