toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Blower Motor Relay > < Ambient Temperature Sensor / Switch HVAC|Locations|Page 2322
Page 1
background image

Blower Motor: Technical Service Bulletins
A/C - Inoperative When Blower Is On High Speed

REFERENCE ELECTRICAL
NUMBER    004
DATE

04-01-88

MODEL

MX 73

TITLE AIR CONDITIONER CIRCUIT BREAKER OPEN CIRCUIT

SYMPTOM:

When maximum fan blower speed is selected, the air conditioner becomes inoperative.

CAUSE:

The air conditioner circuit breaker may open irregularly when the blower motor is operated at maximum-high speed after a
few minutes. This condition is especially prevalent when the vehicle is parked for several hours in extremely high ambient
temperatures.

CORRECTION:

To prevent the circuit breaker from triggering open, the current capacity of the cowl wire No. 2 has been increased in length
and gauge size.

New part #

Part Name

82132-22050

Wire, Cowl No. 2

Production Change

Frame No.

From August, 1987

MX 73-0136834

[Location of Cowl Wire No. 2] Reverse Side of Junction Block

Blower Motor Relay > < Ambient Temperature Sensor / Switch HVAC|Locations|Page 2322