Cressida L6-2759cc 2.8L DOHC (5M-GE) (1988)
Blower Motor: Technical Service Bulletins
A/C - Inoperative When Blower Is On High Speed
REFERENCE ELECTRICAL
NUMBER 004
DATE
04-01-88
MODEL
MX 73
TITLE AIR CONDITIONER CIRCUIT BREAKER OPEN CIRCUIT
SYMPTOM:
When maximum fan blower speed is selected, the air conditioner becomes inoperative.
CAUSE:
The air conditioner circuit breaker may open irregularly when the blower motor is operated at maximum-high speed after a
few minutes. This condition is especially prevalent when the vehicle is parked for several hours in extremely high ambient
temperatures.
CORRECTION:
To prevent the circuit breaker from triggering open, the current capacity of the cowl wire No. 2 has been increased in length
and gauge size.
New part #
Part Name
82132-22050
Wire, Cowl No. 2
Production Change
Frame No.
From August, 1987
MX 73-0136834
[Location of Cowl Wire No. 2] Reverse Side of Junction Block