background image

Fig. 10 Terminal installation with guide plate over ``W''

5.

If adjusting terminal is over ``R'' area, 

Fig. 9, connect adjusting terminal to ``VR'' and ``WB'' terminal. If scale is positioned over ``W'' area, Fig.

10, connect adjusting terminal to ``VR'' and ``YW'' terminal.

6.

Remove jumper.

7.

Reconnect short circuit connector, then install glove box and undercovers.