Cressida L6-3.0L DOHC (7M-GE) (1989)
a. Connect positive lead from battery to terminal 6 and negative lead to terminal 7.
b. Ensure there is continuity between terminals 2 and 4.
10.
On all models, if readings are not as specified, replace relay.
a. Connect positive lead from battery to terminal 6 and negative lead to terminal 7.
b. Ensure there is continuity between terminals 2 and 4.
10.
On all models, if readings are not as specified, replace relay.