Positive Crankcase Ventilation Valve: Service and Repair

REMOVAL 

1. REMOVE VENTILATION VALVE SUB-ASSEMBLY

a. Disconnect the ventilation hose.

b. Remove the ventilation valve.

INSTALLATION 

1. INSTALL VENTILATION VALVE SUB-ASSEMBLY

a. Apply adhesive to 2 or 3 threads of the valve.

Adhesive: Toyota Genuine Adhesive 1324, Three Bond 1344 or the equivalent.