Variable Induction Control Solenoid: Service and Repair

REMOVAL 

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
2. REMOVE V-BANK COVER
3. REMOVE AIR CLEANER ASSEMBLY
4. REMOVE NO. 1 VACUUM SWITCHING VALVE ASSEMBLY

a. Disconnect the connector.
b. Disconnect the 2 vacuum hoses.
c. Remove the bolt and No. 1 vacuum switching valve from the intake air surge tank.

INSTALLATION 

1. INSTALL NO. 1 VACUUM SWITCHING VALVE ASSEMBLY

a. Install the No. 1 vacuum switching valve with the bolt onto the intake air surge tank.

Torque: 9.0 N.m (92 kgf.cm, 80 in.lbf) 

b. Connect the 2 vacuum hoses.
c. Connect the connector.

2. INSTALL AIR CLEANER ASSEMBLY
3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Torque: 3.9 N.m (40 kgf.cm, 35 in.lbf) 

4. INSTALL V-BANK COVER