FJ Cruiser 4WD V6-4.0L (1GR-FE) (2007)
4. Perform the zero point calibration by given the prompts on the tester screen. Refer to the given screen flow.
HINT: Refer to the intelligent tester operator's manual for further details.
OK: COMPLETED is displayed.
5. Perform the sensitivity check by given the prompts on the tester screen.
6. Confirm that the beginning sensor reading is within the standard range.
Standard range: -3.2 to 3.2 kg (-7 to 7 lb)
7. Place a 30 kg (66.14 lb) weight (e.g. a lead mass) onto the front passenger seat.