background image

b. Insulate the removed terminal with insulating tape.

NOTE:  Make sure that the terminal does not stick out from the insulating tape.

c. Remove the 12 bolts and inverter cover.

17. VERIFY THAT VOLTAGE OF W/CONVERTER INVERTER ASSEMBLY IS 0V

CAUTION:  Wear insulating gloves.

NOTE:
-

Make sure that the inverter converter is temporarily installed before working on the converter inverter assembly.

-

Do not allow any foreign objects or waterdrops to enter the w/ converter inverter assembly.

a. Using the voltmeter, measure the voltage between the terminals of the 2 phase connectors (N-P).

Inverter With Converter|Page 2262 > < Inverter With Converter|Page 2260