Highlander 2WD V6-3.3L (3MZ-FE) Hybrid (2006)
![background image](/toyota/highlander_2wd/v6-3.3l_(3mz-fe)_hybrid/Page-536005.png)
b. Remove the 5 bolts, and disconnect the high voltage cables of the Generator from the w/ converter inverter assembly.
20. DISCONNECT MG ECU CONNECTOR
CAUTION: Wear insulating gloves.
NOTE:
-
Make sure that the inverter converter is temporarily installed before working on the converter inverter assembly.
-
Do not allow any foreign objects or waterdrops to enter the w/ converter inverter assembly.
a. Disconnect the 2 connectors and grommets from the w/ converter inverter assembly.
21. DISCONNECT NO.3 WIRE FRAME
CAUTION: Wear insulating gloves.
NOTE:
-
Make sure that the inverter converter is temporarily installed before working on the converter inverter assembly.
-
Insulate the removed terminals with insulating tape.
-
Do not allow any foreign objects or waterdrops to enter the w/ converter inverter assembly.