toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Evaporative Emission Control Canister|Testing and Inspection|Page 2665 > < Canister Purge Volume Control Valve|Testing and Inspection
Page 1
background image

Evaporative Emission Control Canister: Testing and Inspection

CHARCOAL CANISTER ASSY [77740]

SST 09992-00242

a. Visually check the charcoal canister for cracks or damage.

b. Inspect the charcoal canister operation.

1. Plug the vent port with the cap.
2. While holding the purge port closed, blow air (1.76 kPa,18 gf/sq.cm, 0.26 psi) into the EVAP port and check that air flows from the air drain

port.

3. While holding the purge port and the air drain port closed, blow air (1.76 kPa, 18 gf/sq.cm, 0.26 psi) into the EVAP port and check that air

does not flow from the air inlet port.

4. Apply vacuum (3.43 kPa, 25.7 mm.Hg, 1.01 in.Hg) to the purge port, check that the vacuum dose not decrease when the air inlet port is

closed, and check that the vacuum decreases when the air inlet port is released.