Landcruiser 4WD L6-3955cc 4.0L OHV (3F-E) (1988)
![background image](/toyota/landcruiser_4wd/l6-3955cc_4.0l_ohv_(3f-e)/Page-40003.png)
Using an ohmmeter, measure the resistance between the terminal + B and HT.
Resistance (Cold): 5.1 - 6.3 ohms
If the resistance is not as specified, replace the sensor.
Using an ohmmeter, measure the resistance between the terminal + B and HT.
Resistance (Cold): 5.1 - 6.3 ohms
If the resistance is not as specified, replace the sensor.