Valve Clearance: Adjustments

1ZZ-FE ENGINE MECHANICAL: VALVE CLEARANCE:

ADJUSTMENT

1. DISCONNECT BATTERY NEGATIVE TERMINAL
2. REMOVE ENGINE UNDER COVER RH
3. REMOVE CYLINDER HEAD COVER NO.2

(a) Remove the cylinder head cover No. 2  (See: Timing Components/Timing Chain/Service and Repair/Removal).

4. REMOVE IGNITION COIL ASSEMBLY

(a) Remove the ignition coil assembly  (See: Timing Components/Timing Chain/Service and Repair/Removal).

5. REMOVE CYLINDER HEAD COVER SUB-ASSEMBLY

(a) Remove the cylinder head cover sub-assembly  (See: Timing Components/Timing Chain/Service and Repair/Removal).

6. SET NO. 1 CYLINDER TO TDC / COMPRESSION

(a) Set the No. 1 cylinder to the TDC/compression  (See: Timing Components/Timing Chain/Service and Repair/Removal).

7. CHECK VALVE CLEARANCE

(a) Check only the valves indicated.

(1) Using a feeler gauge, measure the clearance between the valve lifter and camshaft.

Valve clearance (Cold):
Intake
0.15 to 0.25 mm (0.0059 to 0.0098 in.)
Exhaust
0.25 to 0.35 mm (0.0098 to 0.0138 in.)

(2) Record any out-of-specification valve clearance measurements. They will be used later to determine the required replacement valve lifters.

(b) Turn the crankshaft 1 revolution (360°) to set the No. 4 cylinder to the TDC/compression.

(c) Check only the valves indicated.

(1) Using a feeler gauge, measure the clearance between the valve lifter and camshaft.

Valve clearance (Cold):
Intake
0.15 to 0.25 mm (0.0059 to 0.0098 in.)
Exhaust
0.25 to 0.35 mm (0.0098 to 0.0138 in.)

(2) Record any out-of-specification valve clearance measurements. They will be used later to determine the required replacement valve lifters.

8. ADJUST VALVE CLEARANCE

(a) Remove the No. 2 camshaft  (See: Camshaft, Lifters and Push Rods/Camshaft/Service and Repair/Removal).
(b) Remove the camshaft  (See: Camshaft, Lifters and Push Rods/Camshaft/Service and Repair/Removal).
(c) Remove the valve lifters.

(d) Using a micrometer, measure the thickness of the removed valve lifters.
(e) Calculate the thickness of a new lifter so that the valve clearance comes within the specified values.