the terminal to be locked securely by two locking devices (the retainer and the lance) to prevent terminals from coming out.

(2) Activation prevention mechanism:

All connectors with an activation prevention mechanism contain a short spring plate. When these connectors are disconnected, the short
spring plate creates a short circuit by automatically connecting the positive (+) and negative (-) terminals of the squib.

(3) Half connection prevention mechanism:

If the connector is not completely connected, the connector is disconnected due to the spring operation so that no continuity exists.

(4) Connector lock mechanism (1):

Locking the connector lock button connects the connector securely.

(5) Connector lock mechanism (2):

Both the primary lock with holder lances and the secondary lock with retainer prevent the connectors from becoming disconnected.

(6) Improper connection prevention lock mechanism:

When connecting the holder, the lever is pushed into the end by rotating around the A axis to lock the holder securely.