toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Canister Purge Control Valve|Service and Repair > < Canister Purge Control Valve|Diagrams
Page 1
background image

Canister Purge Control Valve: Testing and Inspection

2ZR-FE EMISSION CONTROL: PURGE VALVE: INSPECTION

1. INSPECT DUTY VACUUM SWITCHING VALVE

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

(b) Check the operation of the purge VSV.

(1) Check that air does not flow from port E to port F.

(2) Apply battery voltage across terminals 1 and 2.

(3) Check that air flows from port E to port F.

If the result is not as specified, replace the purge VSV.

Canister Purge Control Valve|Service and Repair > < Canister Purge Control Valve|Diagrams