Canister Purge Control Valve: Service and Repair
Installation

2ZR-FE EMISSION CONTROL: PURGE VALVE: INSTALLATION

1. INSTALL DUTY VACUUM SWITCHING VALVE

(a) Install the duty vacuum switching valve with the screw.

Torque : 3.4 Nm (35 kgf-cm, 30 in-lbf)

(b) Connect the duty vacuum switching valve connector, 2 vacuum hoses and wire harness clamp.

2. INSTALL NO. 2 CYLINDER HEAD COVER   See: Engine, Cooling and Exhaust/Engine/Service and Repair/Removal and Replacement/Engine