Previa Van DX 4WD L4-2438cc 2.4L DOHC SC MFI (1997)
(d) Connect the test probe of an ohmmeter to the terminals IDL and E2 of the sensor.
(e) Gradually turn the sensor clockwise until the ohmmeter deflects, and secure it with the 2 set screws.
(f) Recheck the continuity between terminals IDL and E2.
Clearance between lever
Continuity (IDL - E2)
and stop screw
0.50 mm (0.020 inch)
Continuity
0.95 mm (0.037 inch)
No continuity