Refrigerant Pressure Sensor / Switch: Service and Repair

PRESSURE SWITCH

REMOVAL

1.  DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

HINT: 

Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant

Specified amount: 850 ± 50 g (29.98 ± 1.76 oz.)

2.  REMOVE PRESSURE SWITCH

(a)  Disconnect the connector.

(b) Remove the pressure switch from the liquid tube.

Torque: 10 N-m (100 kgf-cm, 7 ft-lbf)

HINT:

Lock the switch mount on the tube with an open end wrench, being careful not to deform the tube, and remove the switch.

At the time of installation, lubricate a new ~ring with compressor oil and install the switch.