Previa Van RWD L4-148.8 2438cc 2.4L DOHC SC (2TZ-FZE) (1996)
Circuit Opening Relay: Testing and Inspection
INSPECTION
1. Remove fuel pump relay.
2. Inspect fuel pump relay.
-
Inspect relay continuity.
-
Using an ohmmeter, check that there is continuity between terminals +B1 and FPR.
-
Check that there is continuity between terminals +B1 and FP.
-
Check that there is no continuity between terminals +B1 and PR.
-
If continuity is not as specified, replace the relay.
-
Inspect relay operation.
-
Apply battery voltage across terminals +B1 and FPR.
-
Using an ohmmeter, check that there is no continuity between terminals +B and FP.
-
Using a voltmeter, check that there is battery voltage between terminals PR and FPR.
-
If operation is not as specified, replace the relay.
3. Reinstall fuel pump relay.