Distributor: Service and Repair

REMOVAL 

1. Disconnect negative (-) terminal cable from battery.

CAUTION:  Work must be started after 90 seconds from the time the ignition switch is turned to the LOCK position and the negative (-) terminal
cable is disconnected from the battery.

2. Remove exhaust pipe heat insulator.

 

-

Remove the 3 bolts, ground Strap and heat insulator.

3. Disconnect high-tension cords from distributor cap.
4. Disconnect distributor connector.
5. Disconnect 2 air hoses.
6. Remove distributor cap and packing.
7. Set No. 1 cylinder to TDC/compression.

-

Install the service bolt (dia.: 12 mm, pitch: 1.25 mm) and nut to the equipment drive pulley.

-

Turn the equipment drive pulley until the timing mark is aligned with the 0 mark on the timing chain case.