toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

All Technical Service Bulletins for Voltage Inverter: > < Hybrid System - MIL ON/DTC P3130, Info Code 346|Page 1786
Page 4
background image

D.

Activate water pump by turning ignition switch to ON position. Allow pump to operate for 20 seconds, then turn the ignition switch to the
OFF position.

E.

Loosen the 2 bleeder plugs to bleed air.

F.

Close the 2 bleeder plugs again.

G.

Repeat steps D - F until the operation sound of the pump decreases and the coolant in the reservoir tank moves faster.

H.

With the ignition switch ON, wait for approximately 5 minutes.

I.

Adjust the coolant level inside the reservoir tank as shown in the illustration.

8.

After replacing the inverter assembly w/converter, clear DTC(s). Even if the master warning light is NOT lit, clear the DTC(s) using a Toyota
Diagnostic Tester.

If a Toyota Diagnostic Tester CANNOT be used, disconnect the auxiliary battery for 1 minute or more and connect it again.

9.

Verify operation of the inverter assembly w/converter after replacement.

Depressing the accelerator pedal to a degree of 50%, increase the speed up to approximately 9 mph (15 km/h) 3 or 4 times to check that there is
NO problem in the inverter operation.

10.

Test drive the vehicle to ensure that all repairs are satisfactory.