toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Ignition Coil > < Ignition Cable|Specifications
Page 1
background image

Ignition Cable: Testing and Inspection

HIGH-TENSION CORDS INSPECTION 

1. DISCONNECT HIGH-TENSION CORDS FROM SPARK PLUGS

Disconnect the high-tension cords at the rubber boot.
Do not pull on the high-tension cords. 

NOTICE: Pulling on or bending the cords may damage the conductor inside.

2. DISCONNECT HIGH-TENSION CORD FROM IGNITION COIL
3. DISCONNECT HIGH-TENSION CORDS FROM DISTRIBUTOR CAP

4. INSPECT HIGH-TENSION CORD RESISTANCE 

Using an ohmmeter, measure the resistance. 

Maximum resistance: 25 k Ohms per cord 

If the resistance is greater than maximum, check the terminals.
If necessary, replace the high-tension cord.

5. RECONNECT HIGH-TENSION CORDS TO DISTRIBUTOR CAP
6. RECONNECT HIGH-TENSION CORD TO IGNITION COIL
7. RECONNECT HIGH-TENSION CORDS TO SPARK PLUGS 

Ignition Coil > < Ignition Cable|Specifications