Key Reminder Switch: Testing and Inspection
System Inspections

Key Unlock Warning Switch

INSPECT KEY UNLOCK WARNING SWITCH CONTINUITY

If continuity is not as specified, replace the switch.

Integration Relay

INTEGRATION RELAY INSPECTION

1. INSPECT RELAY OPERATION

Key Unlock Warning

a. Connect the positive (+) lead from the battery to terminal A1.
b. Connect the negative (-) lead from the battery to terminals A5. A6 and A10.
c. Check the buzzer sounds.

d. Disconnect the negative (-) lead from the battery to terminals A6.
e. Check that the buzzer stops sounding.

f.

Connect the negative (-) lead from the battery to terminals A6.

g. Disconnect the negative (-) lead from the battery to terminals A5.
h. Check that the buzzer stops sounding.

If operation is not as specified, replace the relay.