Variable Valve Timing Solenoid: Testing and Inspection
On-Vehicle Inspection

ON-VEHICLE INSPECTION

INSPECT CAMSHAFT TIMING OIL CONTROL VALVE (OCV) RESISTANCE

a. Disconnect the OCV connector.
b. Using an ohmmeter, measure the resistance between the terminals.

Resistance: 6.9 - 7.9 ohms @ 20 °C (68 °F)

If the resistance is not as specified, replace the OCV. 

c. Reconnect the OCV connector.