toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3104 > < Initial Inspection and Diagnostic Overview|Page 3102
Page 60
background image

(a) Disconnect the E70 No. 3 junction connector.
(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

NG -- REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (NO. 3 JUNCTION CONNECTOR - NO. 2 JUNCTION
CONNECTOR)
OK -- Continue to next step.

17. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 3 JUNCTION CONNECTOR - NO. 4 JUNCTION CONNECTOR)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

NG -- REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (NO. 3 JUNCTION CONNECTOR - NO. 4 JUNCTION
CONNECTOR)
OK -- REPLACE NO. 3 JUNCTION CONNECTOR

Initial Inspection and Diagnostic Overview|Page 3104 > < Initial Inspection and Diagnostic Overview|Page 3102