toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Cooling System > < Water Pump|Specifications|Page 1799
Page 6
background image

b. Apply seal packing to the sealing groove of water inlet housing as shown in the illustration.

Seal packing: Part No. 08826-00100 or equivalent
^

Install a nozzle that has been cut to a 2 - 3 mm (0.08 - 0.12 inch) opening.

^

Parts must be assembled within 3 minutes of application. Otherwise the material must be removed and reapplied.

^

Immediately remove nozzle from the tube and reinstall cap.

c. Install a new O-ring to the water inlet housing.
d. Apply soapy water on the O-ring.
e. Attach the water inlet housing end to the front water bypass joint hole.

f.

Install the water inlet and housing assembly with the 2 bolts. Alternately tighten the bolts. 
Torque: 18 Nm (185 kgf-cm, 13 ft. lbs.) 

HINT:  Each bolt length is indicated in the illustration.

Bolt length:
76 mm (3.00 inch) for A
22 mm (0.87 inch) for B

g. Connect the water bypass hose to the water inlet housing.

3. INSTALL NO.2 IDLER PULLEY
4. INSTALL TIMING BELT
5. FILL WITH ENGINE COOLANT
6. START ENGINE AND CHECK FOR ENGINE COOLANT LEAKS
7. RECHECK ENGINE COOLANT LEVEL

Cooling System > < Water Pump|Specifications|Page 1799