toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

A/C - Poor Compressor Durability|Page 5642 > < A/C - Poor Compressor Durability|Page 5640
Page 1
background image

Hose/Line HVAC: Service and Repair

REPLACEMENT

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

2. REPLACE FAULTY TUBE OR HOSE

NOTE:  Cap the open fittings immediately to keep moisture or dirt out of the system.

3. TIGHTEN JOINT OF BOLT OR NUT AT SPECIFIED TORQUE

NOTE:  Connections should not be torqued tighter than the specified torque.

4. EVACUATE AIR IN REFRIGERATION SYSTEM AND CHARGE SYSTEM WITH REFRIGERANT

Specified amount:
Single A/C: 750 ± 50 g (26.45 ± 1.76 oz.)
Dual A/C: 1050 ± 50 g (37.03 ± 1.76 oz.)

5. INSPECT FOR LEAKAGE OF REFRIGERANT

Using a gas leak detector, check for leakage of refrigerant.

6. INSPECT AIR CONDITIONING OPERATION

A/C - Poor Compressor Durability|Page 5642 > < A/C - Poor Compressor Durability|Page 5640