toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 641
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

HINT:  At the time of installation, please refer to the following item.
Evacuate sir from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.

Specified amount:
Single A/C: 750 ± 50 g (26.45 ± 1.76 oz.)
Dual A/C: 1050 ± 50 g (37.03 ± 1.76 oz.)

2. REMOVE PRESSURE SWITCH FROM LIQUID TUBE

Disconnect the connector and remove the pressure switch.

Torque:  10 N.m (100 kgf.cm, 7 ft.lbf)

HINT:
-

Lock the switch mount on the tube with an open end wrench, being careful not to deform the tube, and remove the switch.

-

At the time of installation, please refer to the following item.
Lubricate a new O-ring with the compressor oil and install them to the switch.

INSTALLATION

Installation is in the reverse order of removal