Page 2
background image

5. DISCONNECT DISCHARGE HOSE SUB-ASSY

a. Remove the bolt and disconnect the discharge hose sub-assy from the cooler condenser core.
b. Remove the O-ring from the discharge hose sub-assy.

NOTE:  Seal the opening of the disconnected parts using vinyl tape to prevent moisture and foreign matters from entering.

6. DISCONNECT COOLER REFRIGERANT LIQUID PIPE A

a. Remove the bolt and disconnect the cooler refrigerant liquid pipe A from the cooler condenser core.
b. Remove the O-ring from the cooler refrigerant liquid pipe A.

NOTE:  Seal the opening of the disconnected parts using vinyl tape to prevent moisture and foreign matters from entering.

7. REMOVE AIR CLEANER INLET NO.2

a. Remove the 2 bolts and the air cleaner inlet No.2.

8. REMOVE AIR CLEANER INLET NO.1