background image

Refrigerant Pressure Sensor / Switch: Testing and Inspection

INSPECT PRESSURE SWITCH NO.1

a. Magnetic clutch control:

Inspect pressure switch operation.
1. Set on the manifold gauge set.
2. Connect the positive (+) lead from the ohmmeter to terminal 2 and the negative (-) lead to terminal 1.
3. Check continuity between terminals when refrigerant pressure is changed, as shown in the illustration.

If operation is not as specified, replace the pressure switch.