3. Connect the tester positive (+) probe to the positive (+) battery (lithium battery) and the tester negative (-) probe to the lead respectively.
4. Press one of the transmission switches on the transmitter for approx. 1 second.
5. Press the transmission switch on the transmitter again to check the voltage.

Standard voltage: 2.2 V or higher 

HINT: 
-

When the temperature of the battery is low, the inspection can not be made correctly. When the outcome of the test is less than 2.2.V,
conduct the test again after leaving the battery in a place at 1.8 °C (64 °F) for more than 30 minutes.

-

The automatic power-off function causes the voltage of the battery to be 2.5 V or more (a voltage with no resistance applied to the
battery) when 0.8 seconds have passed after the switch is pressed. Therefore, make sure to read the voltage just after the switch is
pressed.

-

Since high voltage might be shown once or twice after the battery returns to the specified temperature, the inspection should be made
with the voltage shown after the switch is pressed at least 3 times.

6. Disconnect the lead.

7. Set the battery (lithium battery) in the transmitter.