b. Middle pressure cut side: Inspect pressure switch operation. 

1. Set the manifold gauge.
2. Connect the positive (+) lead from the ohmmeter to terminal 2 and the negative (-) lead to terminal 3.
3. Check continuity between the terminals when refrigerant pressure is changed, as shown in the illustration.

If operation is not specified, replace the liquid tube sub-assembly A.