Solara L4-2.4L (2AZ-FE) (2006)
![background image](/toyota/solara/l4-2.4l_(2az-fe)/Page-1087001.png)
Blower Motor: Testing and Inspection
INSPECTION
1. INSPECT BLOWER RESISTOR
HINT: The blower resistor can be removed following the removal and disassembly procedure for the blower assembly
a. Measure the resistance according to the value(s) in the given table.
If the resistance is not as specified, replace the blower resistor.
2. INSPECT AIR INLET CONTROL SERVOMOTOR (RECIRCULATION DAMPER SERVO SUB-ASSEMBLY)
HINT: The air inlet control servomotor (recirculation damper servo sub-assembly) can be removed following the removal procedure for the
blower assembly
a. Inspect servomotor operation.
1. Connect the positive (+) lead from the battery to terminal 5 and negative (-) lead to terminal 1, then check that the arm turns to the "REC"
side smoothly.
2. Connect the positive (+) lead from the battery to terminal 5 and negative (-) lead to terminal 2, then check that the arm turns to the "FRS"
side smoothly.
If operations are not as specified, replace the servomotor.
3. INSPECT BLOWER W/FAN MOTOR SUB-ASSEMBLY
HINT: The blower w/fan motor sub-assembly can be removed following the removal and disassembly procedure for the blower assembly.