Workshop Manuals Factory service & repair Toyota
01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Hybrid Drive Systems06 Powertrain Management07 Transmission and Drivetrain08 Brakes and Traction Control09 Starting and Charging10 Power and Ground Distribution11 Steering and Suspension12 Heating and Air Conditioning13 Restraint Systems14 Accessories and Optional Equipment15 Body and Frame16 Cruise Control17 Instrument Panel, Gauges and Warning Indicators18 Lighting and Horns19 Windows and Glass20 Wiper and Washer Systems
Toyota Solara V6-3.3L (3MZ-FE) (2004)03 · Maintenance
03 · Maintenance

Refrigerant: Specifications (page 3 of 3)

Make
Toyota
Model
Solara
Engine
V6-3.3L (3MZ-FE)
Year
2004
Section
Fluids › Refrigerant
MaintenanceSpecifications · page 3 of 3
background image

b. Bring the gas leak detector close to the drain hose before performing the test.

HINT:
-

After the blower motor has stopped, leave the cooling unit for more than 15 minutes.

-

Expose the gas leak detector sensor under the drain hose.

-

When bringing the gas leak detector close to the drain hose, make sure that the gas leak detector does not react to the volatile gases.
If such reaction is unavoidable, the vehicle must be lifted up.

c. If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the gas leak

detector sensor into the unit and perform the test.

d. Disconnect the connector and leave the pressure switch for approximately 20 minutes. Bring the gas leak detector close to the pressure switch

and perform the test.

e. Bring the gas leak detector close to the refrigerant lines and perform the test.

Pinch or Ctrl + scroll to zoom. Double-tap to reset.

Parts & tools for this job For 2004 Toyota Solara 3.3L

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.