Solara V6-3.3L (3MZ-FE) (2004)
Wiper Switch: Testing and Inspection
WINDSHIELD WIPER SWITCH ASSY
a. Measure the resistance according to the value(s) in the table.
b. Intermittent Operation Check
1. Connect the voltmeter (+) terminal to terminal C11-7 (+1) of the connector and the voltmeter (-) terminal to terminal C11-2 (EW).
2. Connect the positive battery (+) lead to terminal C11-17 (+B) of the connector and the negative battery (-) lead to terminals C11-2 (EW) and
C11-16 (+S).
3. Turn the wiper switch to the INT position.
4. Connect the positive battery (+) lead to terminal C11-16 (+S) of the connector for 5 seconds.
5. Connect the negative battery (-) lead to terminal C11-16 (+S) of the connector. Operate the intermittent wiper relay and measure the voltage
between terminals C11-7 (+1) and C11-2 (EW).
Standard: Refer to the illustration.