toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Housing Assembly HVAC|Service and Repair > < Air Conditioning Unit|Page 5640
Page 2
background image

2. Connect the positive (+) lead from the battery to terminal 5 and negative (-) lead to terminal 2, then check that the arm turns to the "FRS"

side smoothly.

If operations are not as specified, replace the servomotor.

3. INSPECT BLOWER W/FAN MOTOR SUB-ASSEMBLY

HINT:  The blower w/fan motor sub-assembly can be removed following the removal and disassembly procedure for the blower assembly..

a. Connect the positive (+) lead from the battery to terminal 2 and negative (-) lead to terminal 1, then check that the motor operates smoothly.

If operation is not as specified, replace the blower motor.

Housing Assembly HVAC|Service and Repair > < Air Conditioning Unit|Page 5640