Solara Coupe L4-2.4L (2AZ-FE) (2007)
c. Check for air leakage.
1. With the purge port and air inlet port closed, apply 19.6 kPa (0.2 kgf/sq.cm, 2.81 psi) of pressurized air into the vent port, then confirm
that pressure is retained for 1 minute. If the result is not as specified, replace the charcoal canister assembly.
d. Check the leak detection pump.
1. Remove the 3 bolts and the detection pump from the charcoal canister.
2. Check that air flows from port A to B.
NOTE:
-
Do not damage the O-ring
-
Be careful that the foreign matter does not come in the pump. If the result is not as specified, replace the charcoal canister assembly.
3. Connect the positive (+) lead of the battery to terminal 7 and the negative (-) lead to terminal 6.
4. Check that the valve is closed. If the result is not as specified, replace the charcoal canister assembly.
5. Install the detection pump with the 3 bolts.
Torque: 5.4 N.m (55 kgf.cm, 48 in.lbf)