Supra L6-2997cc 3.0L DOHC MFI (1998)
VSV for EVAP: Testing and Inspection
INSPECTION
1. REMOVE VSV
2. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the terminals.
Resistance :27 - 33 Ohms at 20°C (68°F)
If there is no continuity, replace the VSV.
3. INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is continuity, replace the VSV.
4. INSPECT VSV OPERATION
(a) Check that air does not flow from the ports.
(b) Apply battery positive voltage across the terminals.