4. INSPECT STATOR FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the coil leads.
If there is no continuity, replace the drive end frame assembly.
5. INSPECT STATOR FOR GROUND
Using an ohmmeter, check that there is no continuity between the coil lead and drive end frame.
If there is continuity, replace the drive end frame assembly
6. INSPECT EXPOSED BRUSH LENGTH
Using a vernier caliper, measure the exposed length.
Standard exposed length:
9.5-11.5 mm (0.347-0.453 in.)
Minimum exposed length:
1.5 mm (0.059 in.)
If the exposed length is less than minimum, replace the brush holder.
7. INSPECT POSITIVE RECTIFIER
a. Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.
b. Reverse the polarity of the tester probes and repeat step (a).