T100 Pickup 2WD V6-3.4L (5VZ-FE) (1996)
Ignition Cable: Testing and Inspection
1. REMOVE AIR CLEANER CAP AND MAP METER ASSEMBLY.
2. DISCONNECT HIGH-TENSION CORDS FROM SPARK PLUGS.
-
Disconnect the high - tension cords at the rubber boot.
-
DO NOT pull on the cords.
NOTICE: Pulling on or bending the cords may damage the conductor inside.
3. DISCONNECT HIGH-TENSION CORDS FROM IGNITION COILS.
-
Using a screwdriver. lift up the lock claw and disconnect the holder from the ignition coils.
-
Disconnect the high-tension cord at the grommet.
-
DO NOT pull on the cord.
NOTICE:
-
Pulling on or bending the cords may damage the conductor inside.
-
Do not wipe any of the oil from the grommet after the high-tension cord is disconnected.
4. INSPECT HIGH-TENSION CORD RESISTANCE.
-
Using an ohmmeter, measure the resistance.
Maximum resistance: 25 k Ohms per cord
-
If the resistance is greater than maximum, check the terminals.
-
If necessary, replace the high - tension cord.
5. RECONNECT HIGH-TENSION CORDS TO IGNITION COILS.