toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Charging System > < Electrical - Battery Maintenance and Testing|Page 3771
Page 2
background image

1.

Remove vent caps or covers from the battery cells. NOTE: Do not attempt to remove covers from maintenance-free batteries if so equipped.
Instead, utilize the open-circuit voltage test procedure described in this TSB.

2.

Take the specific gravity readings with a temperature corrected hydrometer. Follow the procedure described by the manufacturer of your
hydrometer.

3.

Record the specific gravity of each cell.

Note:
If a non-temperature corrected hydrometer is being used, the readings need to be adjusted to compensate for electrolyte temperature. For each 10~
F (5.5~ C) above 80~ (26.7~ C), add 0.004 to your readings. For each 10~ F below 80~ F (26.7~ C), subtract 0.0004 from your readings.

TEST RESULTS

1.

A fully charged battery will have a specific gravity reading of approximately 1.265.

2.

The minimum standard for this test is a reading of 1.200. If the reading is less than 1.200, a charge is needed. Follow the previously noted
procedures.

3.

A difference of 30 points (0.030) or more between highest and lowest cell readings indicates a problem battery. Should you encounter this
situation, attempt one recharge using the slow charge method described in this TSB. Allow the battery to stabilize at least 20 minutes after the
charge cycle is complete. Recheck the specific gravity of each cell. If the deviation in cell readings still exceeds 0.030, the battery must be
replaced.

Charging System > < Electrical - Battery Maintenance and Testing|Page 3771