T100 Regular Cab Pickup 2WD L4-2693cc 2.7L DOHC MFI (1998)
Catalytic Converter: Service and Repair
REPLACEMENT
1. REMOVE CENTER EXHAUST PIPE
(a) Disconnect the 2 rings from the support bracket.
(b) Remove the 2 nuts and gasket, and disconnect the heated oxygen sensor (bank 1 sensor 2).
Torque:20 N.m (200 kgf.cm, 14 ft.lbf)
HINT: At the time assembly please refer to the following items. Install the heated oxygen sensor with a new gasket.
(c) Remove the 4 bolts, TWO joint retainer, center exhaust pipe and 2 gasket.
Torque:48 N.m (490 kgf.cm, 35 ft.lbf)
HINT: At the time assembly please refer to the following items. Place 2 new gaskets on the front exhaust and tail pipes, and temporarily
install the center exhaust pipe.
2. REINSTALL CENTER EXHAUST PIPE