T100 Regular Cab Pickup 2WD V6-3.4L (5VZ-FE) (1997)
![background image](/toyota/t100_regular_cab_pickup_2wd/v6-3.4l_(5vz-fe)/Page-923002.png)
(d) Apply vacuum (3.43 kPa, 26 mm Hg, 1.01 in.Hg) to port B. check that the vacuum does not decrease when port C is closed, and check that the
vacuum decreases when port C is released.
(e) While holding port C closed, apply vacuum (1.23 kPa, 9.2 mm Hg, 0.36 in.Hg) to port A and check that air flows into port B.
If a problem is found, replace the charcoal canister. a
(f) Remove the plug.
6. REINSTALL VSV ASSEMBLY
7. REINSTALL CHARCOAL CANISTER
8. RECONNECT EVAP HOSES AND CONNECTORS