toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Bolt Inspection|Page 1289 > < Connecting Rod|Page 1286
Page 1
background image

Connecting Rod: Testing and Inspection
Bolt Inspection

1. Install the cap nut to the connecting rod bolt. Check that the cap nut can be turned easily by hand to the end of the thread.
2. If the cap nut cannot be turned easily, measure the outside diameter of the compressed thread with a vernier caliper. 

Standard outside diameter: 7.860 - 8.000 mm (0.3094 - 0.3150 inch) 
Minimum outside diameter: 7.600 mm (0.2992 inch) 

NOTE:  If the location of minimum diameter cannot be judged by visual inspection, measure the outer diameter at the location shown in the
illustration.

If the outside diameter is less than minimum, replace the connecting rod and rod cap nut as a set.

Bolt Inspection|Page 1289 > < Connecting Rod|Page 1286