toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Ignition Cable|Specifications|Page 1561 > < Ignition Cable|Specifications|Page 1559
Page 1
background image

Ignition Cable: Testing and Inspection

HIGH-TENSION CORDS INSPECTION 

1. REMOVE AIR CLEANER CAP AND MAF METER ASSEMBLY

2. DISCONNECT HIGH-TENSION CORDS FROM SPARK PLUGS

Disconnect the high - tension cords at the rubber boot.
DO NOT pull on the cords.

NOTICE: Pulling on or bending the cords may damage the conductor inside.

3. DISCONNECT HIGH-TENSION CORDS FROM IGNITION COILS

(a) Using a screwdriver, lift up the lock claw and disconnect the holder from the ignition coils.

(b) Disconnect the high-tension cord at the grommet. 

DO NOT pull on the cord.

NOTICE:
-

Pulling on or bending the cords may damage the conductor inside.

-

Do not wipe any of the oil from the grommet after the high-tension cord is disconnected.

4. INSPECT HIGH-TENSION CORD RESISTANCE 

Using an ohmmeter. measure the resistance. 

Maximum resistance: 25 K ohms per cord 

If the resistance is greater than maximum, check the terminals. If necessary. replace the high - tension cord.

Ignition Cable|Specifications|Page 1561 > < Ignition Cable|Specifications|Page 1559