Air Flow Meter/Sensor: Description and Operation

Sensor Schematic

Sensor Cut-Away

CIRCUIT DESCRIPTION 

The mass air flow meter uses a platinum hot wire. The hot wire air flow meter consists of a platinum hot wire, thermistor and a control circuit
installed in a plastic housing. The hot wire air flow meter works on the principle that the hot wire and thermistor located in the intake air bypass of
the housing detect any changes in the intake air temperature.
The hot wire is maintained at the set temperature by controlling the current flow through the hot wire. This current flow is then measured as the
Output voltage of the air flow meter.
The circuit is constructed so that the platinum hot wire and thermistor provide a bridge circuit, with the power transistor controlled so that the
potential of (A) and (B) remains equal to maintain the set temperature.
If the ECM detects DTC "P0100" it operates the fail safe function, keeping the ignition timing and injection volume constant and making it
possible to drive the vehicle.