toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Wiper and Washer Systems > < Diagram Information and Instructions|Page 6316
Page 1
background image

Power Window Motor: Description and Operation

With the ignition SW turned ON, Current flows through the GAUGE fuse to TERMINAL 8 of the Door Lock Control Relay --> TERMINAL 11 -->
to GROUND. This activates the relay and the current flowing to TERMINAL 2 of the relay from POWER fuse flows to TERMINAL 5 of the Relay
--> TERMINAL 9 of the power window master SW and TERMINAL 4 of the power window control SW RH.

1.  MANUAL OPERATION (DRIVER'S WINDOW) 

With the ignition SW turned ON and with the power window master SW (manual SW) in UP position, the current flowing to TERMINAL 9 of
the Power Window Master SW flows to TERMINAL 3 --> TERMINAL 1 of the Power Window Motor --> TERMINAL 2 --> TERMINAL 4
of the master SW --> TERMINAL 6 to GROUND and causes the power window motor to rotate in the up direction. The window ascends only
while the SW is being pushed.

In down operation, the flow of current from TERMINAL 9 of the power window master SW to TERMINAL 4 causes the flow of current from 
TERMINAL 2 of the motor --> TERMINAL 1 --> TERMINAL 3 of the master SW --> TERMINAL 6 --> to GROUND, flowing in the
opposite direction to manual up operation and causing the motor to rotate in reverse, lowering the window.

2.  AUTO DOWN OPERATION

With the ignition SW ON and with the auto SW of the power window master SW in DOWN position, current flowing to TERMINAL 9 of the
master SW flows to TERMINAL 4 of the master SW --> TERMINAL 2 of the power window motor --> TERMINAL 1 --> TERMINAL 3 of
the master SW --> TERMINAL 6 --> to GROUND, causing the motor to rotate towards the down side.

Then the solenoid in the master SW is activated and it locks the auto SW being pushed, causing the motor to continue to rotate in auto down
operation.

When the window has completely descended, the current flow between TERMINAL 3 of the master SW and TERMINAL 6 increases. As a
result, the solenoid stops operating, the auto SW turns OFF and flow from TERMINAL 9 of the master SW to TERMINAL 4 is cut OFF, 
stopping the motor SW that auto stop occurs.

3.  STOPPING OF AUTO DOWN AT DRIVER'S WINDOW

When the manual SW (driver's) is pushed to the up side during auto down operation, a GROUND circuit opens in the master SW and current does
not flow from TERMINAL 3 of the master SW --> to TERMINAL 6, so the motor stops, causing auto down operation to stop. If the manual SW
is pushed continuously, the motor rotates in the up direction in manual up operation.

4. MANUAL OPERATION BY POWER WINDOW CONTROL SW (PASSENGER'S)

With power window SW (passenger's) pushed to the up side, current flowing from TERMINAL 4 of the power window control SW RH flows to 
TERMINAL 3 of the power window control SW --> TERMINAL 2 of the power window motor --> TERMINAL 1 --> TERMINAL 1 of the
power window control SW --> TERMINAL 2 --> TERMINAL 7 of the master SW --> TERMINAL 6 to GROUND and causes the power
window motor (passenger's) to rotate in the up direction. Up operations only while the power window control SW is pushed to the up side. When
the window descends, the current flowing to the motor flows in the opposite direction, from TERMINAL 1 to TERMINAL 2, and the motor
rotates in reverse.

When the window lock SW is pushed to the lock side, the GROUND circuit to the passenger's window becomes open. As a result, even if
open/close operation of the passenger's window is tried, the current from TERMINAL 6 of the power window master SW is not grounded and the
motor does not rotate, so the passenger's window can not be operated and window lock occurs.

5.  KEY OFF POWER WINDOW OPERATION

With the Ignition SW turned from ON to OFF, the door lock control relay operates and current flows from TERMINAL 2 --> TERMINAL 11
--> to GROUND for about 60 seconds. The same as normal operation, the current flows from TERMINAL 2 of the door lock control relay --> 
TERMINAL 5 --> TERMINAL 9 of the power window master SW and from TERMINAL 5 of the door lock control relay --> to TERMINAL
4
 of power window control SW RH. As a result, for about 60 seconds after the ignition SW is turned OFF, it is possible to raise and lower the
power window by the functioning of this relay. Also, by opening the door (door courtesy SW ON) within about 60 seconds after turning the
ignition SW to OFF, a signal is input to TERMINAL 14 or 7 of door lock control relay. As a result, the relay turns OFF, and up and down
movement of the window stops.

Wiper and Washer Systems > < Diagram Information and Instructions|Page 6316