toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Power Window Circuit Breaker|Testing and Inspection|Page 5283 > < Power Window Switch|Testing and Inspection|Page 5278
Page 1
background image

Power Window Circuit Breaker: Testing and Inspection

2 door:

INSPECT CIRCUIT BREAKER OPERATION

a. Disconnect the connector from the master switch.
b. Connect the positive (+) lead from the battery to terminal 3 and the negative (-) lead to terminal 4 on the wire harness side connector, and raise the

window to full closed position.

c. Continue to apply voltage and check that there is a circuit breaker operation noise within approximately 4 - 40 seconds.
d. Reverse the polarity and check that the window begins to descend within approximately 60 seconds.

If operation is not as specified, replace the motor.

4 door:

INSPECT CIRCUIT BREAKER OPERATION

a. Disconnect the connector from the master switch.
b. Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 5 on the wire harness side connector, and raise the

window to full closed position.

Power Window Circuit Breaker|Testing and Inspection|Page 5283 > < Power Window Switch|Testing and Inspection|Page 5278