2. REMOVE BLOWER UNIT

a. Disconnect the connector from the blower motor.

b. Disconnect the air inlet damper control cable from the blower motor.

HINT:  At the time of installation, please refer to the following item.

For installing the control cable, refer to "INSTALLATION" of "HEATER CONTROL ASSEMBLY".

c. Remove the nut, bolt and blower unit.

INSTALLATION

Installation is in the reverse order of removal.

Blower Motor

REMOVAL

1. REMOVE GLOVE COMPARTMENT DOOR

2. REMOVE BLOWER MOTOR

a. Disconnect the connector.
b. Remove the 3 screws and motor.

INSTALLATION

Installation is in the reverse order of removal.