Evaporator Case: Service and Repair
COOLING UNIT REMOVAL
1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
INSTALLATION HINT: Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.
Specified amount:
600 ± 50 g (21.16 ± 1.76 oz.)
2. DISCONNECT LIQUID AND SUCTION TUBES
Loosen the 2 nuts and disconnect the both tubes.
Torque:
Liquid tube: 14 N.m (140 kgf.cm, 10 ft.lbf)
Suction tube: 32 N.m (330 kgf.cm, 24 ft.lbf)
REMOVAL NOTE: Cap the open fittings Immediately to keep moisture or dirt out of the system.
INSTALLATION HINT: Lubricate 2 new O-rings with compressor oil and install the tubes.
3. REMOVE GLOVE COMPARTMENT PARTS
4. REMOVE COOLING UNIT
a. Disconnect the connectors.
b. Remove the 3 screws. 2 nuts and the cooling unit.
COOLING UNIT INSTALLATION
Installation is in the reverse order of removal.