Tercel Sedan 2-Door L4-1497cc 1.5L DOHC (5E-FE) MFI (1997)
c. Turn the ignition switch ON and set the power window switch in the down position.
d. As the window goes down, check that the current flow is approximately 7 A.
e. Check that the current increases up to approximately 14.5 A or more when the window stops going down.
HINT: The circuit breaker opens some 4 - 40 seconds after the window stops going down, so that check must be made before the circuit
breaker operates.
If operation is as specified, replace the master switch.
INSPECT NON-MASTER SWITCH CONTINUITY
Terminal Identification
Reference
Passenger's Door:
Terminal Identification
Reference
Rear Door:
If continuity is not as specified, replace the switch.